Chartered Engineers
Data Centers

AI Data Center Cooling: Liquid Cooling & HVAC System Design

From chip to atmosphere: airflow, cold plates, CDUs, pumps, heat rejection, PUE and WUE for AI data centers.

5.0111 students · 5 ratings 17h· 46 lectures English
Full CourseData Center Mechanical EngineerIntermediateEnglishNew
Secure payment by Stripe - lifetime access - certificate on completion
USD 9.99Udemy list price USD 64.99Save 85%

3-day refund if you have watched less than 15% of the course. Refund policy

Get every course - All-Access USD 29.99/monthPrefer Udemy? View this course on Udemy

What you'll learn

  • Use Claude AI to automate project management tasks using professional prompting techniques
  • Calculate AI rack thermal loads, airflow requirements, coolant flow rates, and supply and return temperatures.
  • Size direct-to-chip cooling loops, CDUs, piping, pumps, and hydraulic systems using engineering calculations.
  • Design HVAC, chilled-water, dry-cooling, adiabatic heat-rejection, and free-cooling solutions for AI facilities.
  • Evaluate immersion cooling, cooling technologies, system architectures, and retrofit strategies.
  • Develop cooling redundancy, leak detection, control strategies, FMEA, and thermal ride-through solutions.
  • Calculate cooling efficiency, PUE, WUE, annual energy consumption, and heat-reuse potential.
  • Integrate cooling design with electrical, structural, and IT systems and prepare mechanical design deliverables.

This course includes

  • 17 hours of on-demand video
  • Practice questions and exam-style quizzes
  • Certificate of completion with verification link
  • Lifetime access on mobile and desktop
  • Included in All-Access membership

Course content

9 sections · 45 lectures · 16h 49m total

Section 01 - Heat, Load and the Thermal Envelope5 · 2h 3m
  • 28:02
  • 24:01
  • ASHRAE Thermal Guidelines (5th Edition) - Air Cooled Classes A1–A4 a22:24
  • Liquid Cooling Classes and Facility Water Temperatures23:14
  • The Cooling Basis of Design for an AI Hall25:52
Section 02 - Air Cooling at High Density5 · 2h 0m
  • Air Side Architectures - CRAH, Fan Walls, In Row and Containment Choices25:12
  • Airflow Sizing, Containment and Pressure Management25:36
  • Rear Door Heat Exchangers and Close Coupled Cooling25:54
  • The Residual Air Load in Liquid Cooled Halls21:03
  • CFD and Thermal Modelling for Design Verification22:26
Section 03 - Direct to Chip Liquid Cooling5 · 1h 46m
  • The Liquid Cooling Taxonomy - Cold Plate, RDHx, Immersion, Single- and Two22:02
  • Cold Plates and the Technology Cooling System22:11
  • Coolants - Water, Propylene Glycol Mixtures and Dielectrics18:43
  • Rack Manifolds, Quick Disconnects and Hoses24:29
  • Two Phase Direct to Chip Cooling19:04
Section 04 - CDUs and Secondary Loops5 · 1h 59m
  • CDU Types and Roles - Liquid to Liquid, Liquid to Air, In Rack and In24:22
  • CDU Sizing - Capacity, Approach Temperature, Flow and Redundancy26:15
  • Secondary Loop Hydraulic Design - Piping, Pressure Drop and Pumps24:10
  • Filtration, Water Quality and Fluid Management19:16
  • Leak Detection, Containment and Liquid in the White Space24:58
Section 05 - Facility Water and Heat Rejection5 · 1h 39m
  • Facility Water System Architecture - Loops, Temperatures and Redundanc16:02
  • Chillers for AI Halls - Selection, Part Load and High Return Temperatu18:39
  • Dry Coolers, Adiabatic and Evaporative Heat Rejection23:00
  • Free Cooling and Economisation20:00
  • Hydraulic Separation, Buffer Tanks and Thermal Storage21:24
Section 06 - Immersion, Technology Choice and Retrofit5 · 1h 47m
  • Single Phase Immersion - Tanks, Fluids and Heat Rejection16:56
  • Two Phase Immersion and Fluid Considerations21:54
  • Immersion Facility Design - Structure, Layout, Maintenance and22:54
  • Comparing Cooling Technologies - Capacity, Efficiency, Cost an28:50
  • Retrofitting Liquid Cooling into Air Cooled Halls16:31
Section 07 - Resilience, Controls and Continuous Cooling5 · 2h 0m
  • Redundancy and Concurrent Maintainability for Cooling System24:53
  • Thermal Ride Through and Continuous Cooling During Power Eve26:27
  • Cooling Controls - Sequences, Setpoints and Stability27:48
  • Monitoring, Sensors and Integration with BMS DCIM20:32
  • Failure Modes and Effects Analysis for Liquid Cooled Halls20:38
Section 08 - Efficiency, Water and Sustainability5 · 1h 39m
  • PUE, WUE and the Mechanical Share27:19
  • Water Use, Water Sources and Water Free Design18:10
  • Heat Reuse - District Heating and Recovery20:50
  • Refrigerants, Fluids and Environmental Regulation18:59
  • Energy Modelling and Annual Performance Simulation13:55
Section 09 - Integration and Capstone5 · 1h 54m
  • Mechanical Design Deliverables by Stage26:06
  • Coordinating Cooling with Electrical, Structural and IT18:53
  • Specifying Liquid Cooling Equipment18:58
  • Designing for the Next Rack Generation25:43
  • Capstone - Cooling Briar Hall B1 from Chip to Atmosphere25:10

Requirements

  • No previous data center experience is required.
  • Basic knowledge of engineering units, formulas, and technical drawings.

About this course

“This course contains the use of artificial intelligence.”

Master the Engineering Behind AI Data Center Cooling Systems — From Chip to Atmosphere.

Artificial intelligence is transforming data center infrastructure. High-density GPU racks, increasingly powerful processors, and advanced computing workloads are creating unprecedented thermal management challenges.

Traditional air-cooling strategies alone are often insufficient for high-density AI environments. Modern facilities increasingly rely on direct-to-chip liquid cooling, cold plates, coolant distribution units (CDUs), advanced HVAC systems, and high-efficiency heat rejection technologies.

This comprehensive masterclass provides a practical, engineering-focused understanding of how these systems are designed, sized, integrated, operated, and optimised.

What You Will Learn

Throughout the course, you will explore:

AI Data Center Thermal Design: Understand server heat loads, rack densities, thermal envelopes, heat transfer fundamentals, and cooling design requirements.

HVAC and Air Cooling Systems: Design airflow strategies using CRAH units, fan walls, containment, in-row cooling, and rear-door heat exchangers.

Direct-to-Chip Liquid Cooling: Explore cold plates, rack manifolds, coolant selection, technology cooling systems, and liquid-cooling architectures.

Coolant Distribution Units: Size CDUs, calculate coolant flow rates, evaluate heat exchanger performance, and select suitable configurations.

Hydraulic Engineering: Calculate pressure losses, pipe sizing, pump head, pumping power, and system performance.

Heat Rejection Systems: Understand chillers, dry coolers, adiabatic systems, free cooling, and facility water networks.

Immersion Cooling: Evaluate single-phase and two-phase immersion technologies, applications, and engineering considerations.

Cooling Reliability and Resilience: Develop redundancy strategies, controls, monitoring, leak detection, failure analysis, and thermal ride-through solutions.

Energy Efficiency and Sustainability: Calculate PUE, WUE, annual cooling energy, water consumption, and heat-reuse opportunities.

Integrated Cooling Design: Coordinate mechanical systems with electrical, structural, IT, and facility infrastructure.

Practical Engineering Calculations and Case Studies

Unlike courses focused primarily on general concepts, this program emphasises engineering calculations and design decisions.

You will follow a fictional AI data center project through a complete cooling design process, including thermal load calculations, airflow sizing, coolant flow, piping hydraulics, pump selection, CDU sizing, heat rejection, redundancy, and performance assessment.

Worked examples explain the formulas, input values, calculation steps, engineering results, and design interpretations.

Comprehensive Learning Resources

The course package includes:

45 structured lessons covering the AI data center cooling lifecycle.

913 pages of technical lesson materials, supplied across 45 PDF study documents.

267 Excel-based calculation tools supporting thermal and hydraulic engineering.

Worked engineering examples with formulas, units, and design interpretations.

Scenario-based practice questions with detailed answer reviews.

An integrated fictional AI data center case study.

Design checklists, revision materials, and supporting resource guides.

These resources are designed to help you develop a structured understanding of the engineering decisions behind modern cooling infrastructure.

Who Should Enrol?

This masterclass is suitable for mechanical engineers, HVAC engineers, data center designers, building services professionals, design managers, technical project managers, and engineers transitioning into AI and high-density digital infrastructure.

Whether you are entering the data center industry or expanding your knowledge of advanced cooling technologies, this course provides a comprehensive technical learning pathway.

Build your understanding of AI data center cooling — from the chip, through the cooling infrastructure, to the atmosphere.

Important: All calculations are provided for educational purposes and are not construction-ready designs. The course is an independent educational product and is not affiliated with, approved or endorsed by ASHRAE, OCP, Uptime Institute, NVIDIA, or any equipment manufacturer. Fictional project details and figures are used for teaching purposes. The course does not prepare learners for an official certification.

Who this course is for

  • Mechanical and HVAC engineers working on data center cooling systems.
  • Mechanical and HVAC engineers working on data center cooling systems.
  • Engineers interested in direct-to-chip liquid cooling and immersion cooling technologies.
  • Design managers and owner's engineers responsible for reviewing technical designs.
  • Industrial, process, and facilities engineers transitioning into high-density computing infrastructure.

Frequently Asked Questions

Does the course cover liquid cooling?+

Yes. It covers cold plates, CDUs and pumps as well as air-side cooling and heat rejection.

Are efficiency metrics included?+

Yes. PUE and WUE are explained and applied.

Do I need to be a mechanical engineer?+

Not necessarily. A basic HVAC background helps, and concepts are built up step by step.

How long is the course?+

It contains 46 lectures and around 17 hours of content on Udemy.